12 March 1999 FUSING UNIT
SM 6-7 G031/G032
Replacement
and
Adjustment
6.2.3 PRESSURE ROLLER REPLACEMENT
1. Perform steps 1 to 5 of Hot Roller and Fusing Lamp Replacement, section
6.2.2.
2. G031 only: Remove the exit guide plate [A] (2 screws).
3. G031 only: Remove the entrance guide [B] (3 screws).
4. Remove the pressure arms [C].
5. Remove the bushings [D].
6. Replace the pressure roller [E].
NOTE:
1) When re-installing the pressure roller, make sure that the green pin
[F] is at the left side, as shown (near the fusing exit sensor).
2) Do not touch the pressure roller with your bare hands.
G031R555.WMF
G031R543.WMF
[B]
[A]
[D]
[C]
[E]
[F]
[D]
[C]