Savin SPC210SF Uživatelský manuál Strana 14

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 17
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 13
Product Support Guide G157
Version 1.3
14
Necessary Settings
The PM counter initialization (Service Mode > 36 Clear Care) must be performed
after the following units are replaced:
Transfer Belt Unit
Transfer Roller
Transfer Belt Cleaning Unit
Paper Feed Roller
Separator Pad
Fusing Unit
Expected yield based on P/J
Expected Yield
Item
1P/J 2P/J 3P/J 5P/J
Waste Toner Bottle
(maintenance Kit)
3.54k prints
(7.8k dev.)
4.18k prints
(9.2k dev.)
4.45k prints
(9.8k dev.)
4.59k prints
(10.1k dev.)
OPC Belt Unit
(Maintenance Kit)
10.9k prints
(24k dev.)
15k prints
(33k dev.)
17.7k prints
(39k dev.)
19.5k prints
(43k dev.)
Fusing Unit
(Service Parts)
28k prints 47k prints 55k prints 60k prints
Note: The figures in the tables above are calculated under the following conditions: LT SEF, 5%
image coverage ratio, 40% color ratio
Total Counter Information
The total counter can be viewed on the display panel or printed out. Counters
that can be accessed: total page, fax, print, and copy count.
To view the counters on the Operation panel: Press Menu/Set, 7, 2.
To print out counters: Press Menu/Set, 5, 5, black start. The User
Settings List will be output.
Example of User Settings List
TOTAL :000816
COPY :000060
PRINT :000735
FAX/LIST :000017