1.2 DRUM UNIT
1. Make sure that the drum unit is set in position and the drum stay is
secured with a screw when the main switch is turned on. If the drum unit
is loose, poor contact of the drum connectors may cause electrical noise,
resulting in unexpected malfunctions (RAM data may change in the worst
case).
2. Insert a clean sheet of paper between the drum and the drum charge
roller and also cover the OPC drum with paper when you leave the drum
unit out of the copier more than 30 minutes. Doing so prevents the drum
charge roller from sticking to the drum. If the drum charge roller sticks to
the drum, the chemical component of the drum charge roller affects the
surface of OPC drum.
1.3 DRUM CHARGE ROLLER
1. Do not touch the drum charge roller with bare hands. Oil stains may
cause black bands on copies due to excessive drum charge.
2. Do not adhere toner or setting powder dust to the drum charge roller.
Toner stains or setting power may cause white spots or white bands on
copies due to insufficient drum charge.
3. Prevent the drum charge roller from being exposed to dusty air. Dust on
the drum charge roller may cause white spots on copies due to
insufficient drum charge.
4. Never use alcohol or water to clean the drum charge roller. Alcohol or
water corrode the surface of the drum charge roller. Wipe with a dry cloth
or a Dupont Sontara DY-12 cloth - P/N A1539004.
5. Reduce the drum charge roller cleaning intervals with SP2-901 as
follows for users who mainly make high volume copy runs continuously.
SP2-901 setting Cleaning interval
0 ..................... Every 1000 copies for 10 seconds [default]
1 ..................... Every 500 copies for 10 seconds
2 ..................... Every 200 copies for 10 seconds
3 ..................... Every 100 copies for 10 seconds
6. Plug in the copier power cord even when the copier main switch is turned
off. While the main switch is turned off, the drum heater must be turned
on to keep the temperature around the drum charge roller over 15°C.
This prevents the drum charge efficiency from being low for the first copy
after the power is switched on.