Installation and Operating Instructions
SDC 306 1316BED036-11B-E Date 06/09
- 42 -
11.11 Basic system diagram 11:
1 collector array, 1 storage cylinder, swimming pool, return line temperature increase
System 11 has one collector surface, one
storage cylinder, one swimming pool and
one return line temperature increase. The
control unit controls the solar function
(temperature difference regulation for
storage cylinder and swimming pool, priority
logic), and the return line temperature
increase (temperature difference
regulation). Heat metering is also possible,
e.g. using an impeller flow meter.
Info Program Manual operation Basic setting
I I I I
Current collector temperature (E1) Maximum temperature of
storage cylinder 1
Pump A1 off/on Code entry
Minimum collector temperature (E1) Solar circuit storage cylinder
1 Td Start
A2 off/on Reset/factory setting
Maximum collector temperature (E1) Solar circuit storage cylinder
1 Td Stop
A3 off/on Select basic
configuration
Current temperature of storage cylinder 1
at bottom (E2)
Maximum temperature of
swimming pool
A4 off/on Maximum collector
temperature
Min. temp. of storage 1 at bottom (E2) Solar circuit pool Td start Priority storage cylinder
Max. temp. of storage 1 - bottom (E2) Solar circuit pool Td stop Mode yield metering
Current temp. of storage 1 - centre (E4) R2 Td start
Volume flow
Minimum temp. of storage 1 - centre (E4)
R2 Td stop
DFG/WMM
∗∗
Max. temp. of storage 1 - centre (E4) Set time
Glycol type
Current return line temperature (E5) Maintenance
(summer/winter)
Glycol percentage
Minimum return line temperature (E5) Code change
Maximum return line temperature (E5)
Current swimming pool temp. (E3)
Minimum swimming pool temp. (E3)
Maximum swimming pool temp. (E3)
Flow rate
Daily yield 1/2
Total yield 1/2
Displayed only if yield metering mode is equivalent to 1 or 2.
∗∗ Displayed only if yield metering mode is equivalent to 2.